5.1 Monitoring
The System 5 monitor system accommodates multiformat outputs up to 7.1 channels.
There are seven monitor outputs (Figure 5-2):
The Main Control Room and Mon A (7.1 max)
Alt 1 (5.1 max)
Alt 2, Mon B, C, and D route two busses (stereo)
Mon A, B, C, and D are used for SLS/Cue feeds.
Figure 5-2 Monitoring Matrix
Source selection for the monitor output can either intercancel (only one source to a
monitor output), or sum (multiple sources). The Control Room monitor outputs can be
folded down from their multichannel formats (see Folddown on page 59).
NOTE: Group bus outputs are normally monitored on the Strips but can be routed us-
ing external inputs and PatchNet if they require direct monitoring.
5.1.1 Monitor Source Selection
The sources for Mon A–D and Control Room outputs are selected using the Panel
Viewer. Press the Mon A–D or CR Source buttons to display available sources
(Figure 5-3 shows the Mon D Source Panel).
Externals Mix Stems Aux Snd s
CR
Monitors
8 Out (max 7.1)
Mon A
8 Out (max 7.1)
Alt 2
Stereo
Alt 1
6 Out (Max 5.1)
Main
8 Out (max 7.1)
Mon B
Stereo
Mon C
Stereo
Mon D
Stere
o
Monitor Selector
Stem
Rtn
Stem
Page view 63