Euphonix Modular I/O Specifications Page 133

  • Download
  • Add to my manuals
  • Print
  • Page
    / 170
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 132
Chapter 11: Dolby D/E Modules 133
Using the CAN Address switches on the FC972 or SY983 is an older method of setting the Frame ID. An explicit CAN Address must
be set only when employing a hardware CAN-BUS remote controller to configure frames. In System 5, the Frame ID is set with
the FC972’s IP Address for configuration using a web browser interface.
To set the CAN ID in range 0–15:
1 Set SW1-B to OFF.
2 Use the CAN Rotary Switch to set the CAN ID.
To set the CAN ID in range 16–31:
1 Set SW1-B to ON.
2 Use the CAN Rotary Switch to set the CAN ID.
Status LEDs
Green OK
Red Bad
Flashing The module is in focus of the frame controller
Green Under GUI control
Dolby D LEDs
Red Reading a proper Dolby D signal
Off Dolby D decoding error
Dolby E LEDs
Blue Reading a proper Dolby E signal
Off Dolby E decoding error